  "title": "Residential & commercial building energy demand profiles under different retrofit scenarios (CESAR model)",
  "category": "Demand hourly profiles",
"keywords": ["Residential","Commercial","Retrofit","CESAR","Archetypes"],
"description": "Hourly space and water heating, cooling and electricity demand profiles for a selected set of archetype buildings in Switzerland, under 2 envelope retrofit scenarios; includes single-family residential, Multi-family residential, Office, School, Shop, Restaurant and Hospital; based on results from simulations with the CESAR model.",
"version": "2020-09-17",
"last_updated": "2020-09-17",
"contributors": [{"title": "Andrew Bollinger", "email": "andrew.bollinger@empa.ch"},{"title": "Portia Murray", "email": "portia.murray@empa.ch"}],
  "licenses" : "",
 "resources": [
    {
      "name": "Hourly profiles in the residential sector for single and multi-family houses, by age type and retrofit scenario",
      "path": "residential_hour_profile_EMPA.csv",
      "mediatype": "text/csv",
      "schema": {
        "fields": [
          	{
	            "constraints": {
	              "required": true
	        	},
				"description": "Date/Time", 
	       		"name": "Date of the year (01/01 to 31/12) and time of the day (01:00-24:00)",
	        	"type": "text"
      		},
          {
              "constraints": {
                "required": true
            },
        "description": "Building_type", 
            "name": "SFH and MFH",
            "type": "text"
          },
      		{
	            "constraints": {
	              "required": true
	        	},
				"description": "Construction period: Before 1920, 1920-1945, 1946-1960, 1961-1970, 1971-1980, 1981-1985, 1986-1990, 1991-1995, 1996-2000, 2001-2005, 2006-2010 and 2011-2015", 
	       		"name": "Category",
	        	"type": "text"
      		},
          {
              "constraints": {
                "required": true
            },
        "description": "Retrofit scenario: Full retrofit and No retrofit", 
            "name": "retrofit_scenario",
            "type": "text"
          },
          	{
            "constraints": {
              	"required": true
        		},
                "description": "Hourly Hot water and space heating demand in Joules", 
        		"name": "Hot water + Space Heating demand [J](Hourly)",
        		"type": "number"
      		},
          	{
            "constraints": {
              "required": true
        	},
            "description": "Hourly space heating demand in Joules", 
        	"name": "Space Heating demand [J](Hourly)",
        	"type": "number"
      		},
            {
            "constraints": {
              "required": true
          },
            "description": "Hourly hot water demand in Joules", 
          "name": "Hot water demand [J](Hourly)",
          "type": "number"
          },
            {
            "constraints": {
              "required": true
          },
            "description": "Hourly space cooling demand in Joules", 
          "name": "Space cooling demand [J](Hourly)",
          "type": "number"
          },
            {
            "constraints": {
              "required": true
          },
            "description": "Hourlye electricity demand in Joules", 
          "name": "Electricity demand [J](Hourly) ",
          "type": "number"
          }
         ]
      }
    },
    {
      "name": "Hourly profiles in the commercial sector for hospitals, offices, restaurants, schools and shops , by age type and retrofit scenario",
      "path": "commercial_hour_profile_EMPA.csv",
      "mediatype": "text/csv",
      "schema": {
        "fields": [
            {
              "constraints": {
                "required": true
            },
        "description": "Date/Time", 
            "name": "Date of the year (01/01 to 31/12) and time of the day (01:00-24:00)",
            "type": "text"
          },
          {
              "constraints": {
                "required": true
            },
        "description": "Building_type", 
            "name": "Hospitals, Offices, Restaurants, Schools and Shops",
            "type": "text"
          },
          {
              "constraints": {
                "required": true
            },
        "description": "Construction period: Before 1920, 1920-1945, 1946-1960, 1961-1970, 1971-1980, 1981-1990, 1991-2000, 2001-2010 and 2011-2015", 
            "name": "Category",
            "type": "text"
          },
          {
              "constraints": {
                "required": true
            },
        "description": "Retrofit scenario: Full retrofit and No retrofit", 
            "name": "retrofit_scenario",
            "type": "text"
          },
            {
            "constraints": {
                "required": true
            },
                "description": "Hourly Hot water and space heating demand in Joules", 
            "name": "Hot water + Space Heating demand [J](Hourly)",
            "type": "number"
          },
            {
            "constraints": {
              "required": true
          },
            "description": "Hourly space heating demand in Joules", 
          "name": "Space Heating demand [J](Hourly)",
          "type": "number"
          },
            {
            "constraints": {
              "required": true
          },
            "description": "Hourly hot water demand in Joules", 
          "name": "Hot water demand [J](Hourly)",
          "type": "number"
          },
            {
            "constraints": {
              "required": true
          },
            "description": "Hourly space cooling demand in Joules", 
          "name": "Space cooling demand [J](Hourly)",
          "type": "number"
          },
            {
            "constraints": {
              "required": true
          },
            "description": "Hourlye electricity demand in Joules", 
          "name": "Electricity demand [J](Hourly) ",
          "type": "number"
          }
         ]
      }
    }
  ],
  "sources": [
       {"name": "Optimal transformation strategies for buildings, neighbourhoods and districts to reach CO2 emission reduction targets", "web": "https://www.sciencedirect.com/science/article/pii/S0378778819319486"}
    ]
}