  "description": "Data (costs, efficiency, lifetime) for energy electricity technologies - PSI study",
 "version": "2019-03-29",
 "keywords": [
              "technology",
              "characteristics"
  ],
 "category": "Technologies",
 "last_updated": "2019-03-29",
 "license": "",
 "title": "Electricity generation technologies in PSI Study",
 "contributors": [{"title": "Christian Bauer", "email": "christian.bauer@psi.ch"}],
  "resources": [
    {
      "name": "electricity-generation-technologies-psi",
      "path": "electricity-generation-technologies-psi.csv",
      "mediatype": "text/csv",
       "tag":[
              "technology",
              "electricity",
              "cost",
              "efficiency"
      ],
      "schema": {
        "fields": [
          {
            "constraints": {
              "required": true
        },
                    "description": "Name of technology", 
        "name": "Technology",
        "type": "string"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Year", 
        "name": "Year",
        "type": "string"
      },
         {
            "constraints": {
              "required": true
        },
                    "description": "Reference installation size", 
        "name": "Size (MW)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Overnight specific investment costs: reference value", 
        "name": "Inv_ref (CHF/kW)",
        "type": "number"
      },
                {
            "constraints": {
              "required": true
        },
                    "description": "Overnight specific investment costs: low value", 
        "name": "Inv_low (CHF/kW)",
        "type": "number"
      },
                {
            "constraints": {
              "required": true
        },
                    "description": "Overnight specific investment costs: high value", 
        "name": "Inv_high (CHF/kW)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Fixed operating and maintenance costs: reference value", 
        "name": "FOM_ref (CHF/kW*a)",
        "type": "number"
      },
                {
            "constraints": {
              "required": true
        },
                    "description": "Fixed operating and maintenance costs: low value", 
        "name": "FOM_low (CHF/kW*a)",
        "type": "number"
      },
                {
            "constraints": {
              "required": true
        },
                    "description": "Fixed operating and maintenance costs: high value", 
        "name": "FOM_high (CHF/kW*a)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Variable operating and maintenance costs", 
        "name": "VOM (Rp/kWh)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Dismantling cost", 
        "name": "Dec (CHF/kW)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Electric efficiency: reference value", 
        "name": "Eff_elc_ref (%)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Electric efficiency: low value", 
        "name": "Eff_elc_low (%)",
        "type": "number"
      },
         {
            "constraints": {
              "required": true
        },
                    "description": "Electric efficiency: high value", 
        "name": "Eff_elc_high (%)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Thermal efficiency: reference value", 
        "name": "Eff_th_ref (%)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Thermal efficiency: low value", 
        "name": "Eff_th_low (%)",
        "type": "number"
      },
                     {
            "constraints": {
              "required": true
        },
                    "description": "Thermal efficiency: high value", 
        "name": "Eff_th_high (%)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Percentage of CO2 emissions captured: reference value", 
        "name": "CO2 cap_ref (%)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Percentage of CO2 emissions captured: low value", 
        "name": "CO2 cap_low (%)",
        "type": "number"
      },
                      {
            "constraints": {
              "required": true
        },
                    "description": "Percentage of CO2 emissions captured: high value", 
        "name": "CO2 cap_high (%)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Technical lifetime: reference value", 
        "name": "Life_ref (yrs)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Technical lifetime: low value", 
        "name": "Life_low (yrs)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Technical lifetime: high value", 
        "name": "Life_high (yrs)",
        "type": "number"
      },
          {
            "constraints": {
              "required": true
        },
                    "description": "Page in the report where the data can be found", 
        "name": "Page",
        "type": "string"
      }
  		]
      }
    }
  ],
  "sources": [
    { "name": "Bauer, C., S. Hirschberg (eds.), Y. Bäuerle, S. Biollaz, A. Calbry-Muzyka, B. Cox, T. Heck, M. Lehnert, A. Meier, H.-M. Prasser, W. Schenler, K. Treyer, F. Vogel, H.C. Wieckert, X. Zhang, M. Zimmermann, V. Burg, G. Bowman, M. Erni, M. Saar, M.Q. Tran (2017) “Potentials, costs and environmental assessment of electricity generation technologies.” PSI, WSL, ETHZ, EPFL. Paul Scherrer Institut, Villigen PSI, Switzerland.", "web": "https://www.psi.ch/ta/PublicationTab/Final-Report-BFE-Project.pdf"}
   ]
}
