Jump to Data Package:
Residential & commercial building energy demand profiles under different retrofit scenarios (CESAR model)
Package version | |
Description | Hourly space and water heating, cooling and electricity demand profiles for a selected set of archetype buildings in Switzerland, under 2 envelope retrofit scenarios; includes single-family residential, Multi-family residential, Office, School, Shop, Restaurant and Hospital; based on results from simulations with the CESAR model. |
Last changes | Not documented. |
Download |
Data package (zip) jasm-demand-hourly-profile-retrofits-cesar-2020-09-17.zip (9 MB) Individual data files (csv, xlsx) residential_hour_profile_EMPA.csv (32 MB) commercial_hour_profile_EMPA.csv (33 MB) |
Meta data |
README.md datapackage.json |
Sources | Optimal transformation strategies for buildings, neighbourhoods and districts to reach CO2 emission reduction targets |
Contact | Andrew Bollinger | Portia Murray |
Field documentation
Hourly profiles in the residential sector for single and multi-family houses, by age type and retrofit scenario (residential hour profile EMPA.csv)
Field Name | Type (Format) | Description |
---|---|---|
Date of the year (01/01 to 31/12) and time of the day (01:00-24:00) | text | Date/Time |
SFH and MFH | text | Building_type |
Category | text | Construction period: Before 1920, 1920-1945, 1946-1960, 1961-1970, 1971-1980, 1981-1985, 1986-1990, 1991-1995, 1996-2000, 2001-2005, 2006-2010 and 2011-2015 |
retrofit_scenario | text | Retrofit scenario: Full retrofit and No retrofit |
Hot water + Space Heating demand [J](Hourly) | number | Hourly Hot water and space heating demand in Joules |
Space Heating demand [J](Hourly) | number | Hourly space heating demand in Joules |
Hot water demand [J](Hourly) | number | Hourly hot water demand in Joules |
Space cooling demand [J](Hourly) | number | Hourly space cooling demand in Joules |
Electricity demand [J](Hourly) | number | Hourlye electricity demand in Joules |
Hourly profiles in the commercial sector for hospitals, offices, restaurants, schools and shops , by age type and retrofit scenario (commercial hour profile EMPA.csv)
Field Name | Type (Format) | Description |
---|---|---|
Date of the year (01/01 to 31/12) and time of the day (01:00-24:00) | text | Date/Time |
Hospitals, Offices, Restaurants, Schools and Shops | text | Building_type |
Category | text | Construction period: Before 1920, 1920-1945, 1946-1960, 1961-1970, 1971-1980, 1981-1990, 1991-2000, 2001-2010 and 2011-2015 |
retrofit_scenario | text | Retrofit scenario: Full retrofit and No retrofit |
Hot water + Space Heating demand [J](Hourly) | number | Hourly Hot water and space heating demand in Joules |
Space Heating demand [J](Hourly) | number | Hourly space heating demand in Joules |
Hot water demand [J](Hourly) | number | Hourly hot water demand in Joules |
Space cooling demand [J](Hourly) | number | Hourly space cooling demand in Joules |
Electricity demand [J](Hourly) | number | Hourlye electricity demand in Joules |